October 30, 2024

PUCO’s Porter Submits Resignation

By Ted Caddell

Andre T. Porter, the chairman of the Public Utilities Commission of Ohio, submitted his resignation to Gov. John Kasich on Friday morning, little more than a year after taking the position and less than a month after shepherding through controversial power purchase agreements for FirstEnergy and AEP Ohio.

puco andre porter
Photo Credit: Kevin Graff (Ohio Citizen Action)

“At this time, my wife and I have made the very difficult decision to pursue a new opportunity for our family back in the private sector,” he wrote to Kasich. “With mixed emotions, I must inform you that I will resign as PUCO commissioner effective as of the close of business on May 20, 2016.”

Porter did not say where he was going, but rumors have been rippling through the utility industry that he has taken a position with an RTO. At yesterday’s PJM Markets and Reliability Committee meeting, CFO Suzanne Daugherty addressed the rumors, saying Porter was not coming to PJM.

Stakeholders and PJM officials said privately they believe Porter is headed to MISO. Officials at MISO did not respond to requests for comment Friday morning.

Porter, an attorney, was not available for comment, according Holly Karg, director of public affairs for the commission. She said he has not indicated where he is going, and said he would not be issuing any further comments today.

“We very much appreciate Andre Porter’s distinguished record of public service as a member of the governor’s cabinet where he directed the Ohio Department of Commerce and — in an independent role — as commissioner and most recently chairman of the Public Utilities Commission,” said Joe Andrews, Kasich’s press secretary, in a prepared statement.

Before working at the state’s Commerce Department, Porter served as a commissioner from 2011 to 2013. His current term wasn’t scheduled to expire until April 2020.

“When I joined state government in 2011, I did so with the personal aspiration to be impactful within an allotted period of time,” Porter wrote in his letter. “At the PUCO, while working independently of the administration, I’ve led the commission in addressing some of the most challenging utility issues in recent history.”

The eight-year PPAs Porter and fellow commissioners approved for FirstEnergy and AEP Ohio last month are at risk following FERC’s decision Wednesday to rescind the companies’ affiliate sales waivers. (See FERC Rescinds AEP, FirstEnergy Affiliate-Sales Waivers; Will Review Ohio PPAs.)

Suzanne Herel contributed to this report.

FERC Rescinds AEP, FirstEnergy Affiliate-Sales Waivers

AEP to Seek Reregulation, Plant Sales

By Suzanne Herel and Ted Caddell

FERC late Wednesday rescinded waivers it granted American Electric Power and FirstEnergy, meaning the controversial power purchase agreements approved by Ohio regulators will be subject to the commission’s affiliate abuse test.

The commission granted a request by the Electric Power Supply Association and others asking it to rescind the affiliate sales waivers it gave AEP in 2014 (EL16-33) and FirstEnergy in 2008 (EL16-34) based on Ohio’s retail choice law.

The commission said despite retail choice, the company’s ratepayers were essentially “captive” customers because the PPAs, approved by the Public Utilities Commission of Ohio on March 31, would impose on them non-bypassable distribution charges.

“These non-bypassable charges present the ‘potential for the inappropriate transfer of benefits from [captive] customers to the shareholders of the franchised public utility,’ and, thus, could undermine the goal of the commission’s affiliate restrictions,” FERC said.

As a result, the PPAs will be subject to FERC’s Edgar test, which will require the companies to prove the lack of affiliate abuse by evidence of head-to-head competition, or benchmarks such as prices that non-affiliated buyers are willing to pay.

That will be a difficult hurdle for the companies to clear, as the PPAs were not subject to competition, and critics say they could impose billions in extra costs on consumers.

FirstEnergy shares dropped 4.85% in after-hours trading. AEP shares were down 1.2%.

Lifeline

FirstEnergy and AEP have said the PPAs are crucial to keeping some of their underperforming coal-fired plants running in the state.

In approving the eight-year contracts, Ohio regulators said they were striving for “rate stability” by building in safeguards intended to protect consumers, modifying the plans to limit bill increases. The commission also added provisions meant to “encourage” grid modernization and retail competition. (See FERC Action Awaited Following PUCO OK on PPAs.)

Although the PPAs guarantee the generators receive revenue streams above current market prices, AEP and FirstEnergy contend the deals will save customers money if natural gas prices increase.

FirstEnergy spokesman Doug Colafella said the company was disappointed in the ruling. “Our affiliate FirstEnergy Solutions was previously granted authorization to conduct transactions with our Ohio utilities in 2008, and the PPA will benefit our customers by protecting them against rising retail prices and volatility in future years.

“We also believe that the PPA complies with existing FERC rules that promote retail shopping, and our Ohio customers will continue to have the ability to choose a competitive supplier. FirstEnergy is evaluating its options, which include seeking rehearing of FERC’s order, as well as filing the PPA for FERC’s review. It’s always been our position that the PPA will satisfy the FERC’s criteria for an affiliate contract.”

AEP: Reregulate Ohio

On an earnings call Thursday, AEP CEO Nick Akins said the company would lobby Ohio legislators to reregulate the power market — or sell all its generation — as a result of the FERC ruling.

“FERC’s decision to require review of the AEP Ohio power purchase agreement is a disappointing and unfortunate intrusion by FERC into Ohio’s ability to define its own long-term electricity supply and protect customers and the state economy from electricity price spikes and market volatility,” a clearly frustrated Akins said on the call.

“Although we believe the AEP Ohio power purchase agreement is the best long-term approach for our Ohio customers and the state and that it would survive FERC review, AEP is not interested in participating in a drawn-out FERC review process,” he said.

“We are focused on being a regulated utility company, so we will initiate a strategic review of the generation assets in the power purchase agreement, similar to the review already in place for our other competitive generation assets. At the same time, we also will advocate for legislation in Ohio that would reregulate generation in the state or provide a mechanism for AEP Ohio to own and develop generation assets, including the plants included in the PPA and renewables.”

EPSA Challenge

EPSA, the Retail Energy Supply Association, Dynegy, NRG Energy and GenOn Energy Management had asked FERC to rescind the waivers to ensure a Section 205 review of the eight-year PPAs. (See Dynegy, NRG Ask FERC to Void Ohio PPAs.)

In its companion orders, FERC agreed with the complainants that the affected customers are essentially captive. In addition, in the case of FirstEnergy, “the commission addressed the more general concern raised by a protester that FirstEnergy’s electric security plan proposal would create barriers to competition.”

The commission directed AEP and FirstEnergy to revise their market-based rate tariffs within 30 days and file notices of a change in status “addressing whether this change in circumstances affects any other waivers the commission previously granted.”

ferc, puco, ppas, AEP, FirstEnergy
AEP’s Conesville Power Station (© Delta Whiskey, Creative Commons)

On Wednesday night, EPSA released a statement saying it was still reviewing the orders.

“Tonight, FERC issued orders (without dissent) granting the complaints EPSA, with support from a broad coalition of consumers, environmental groups and others, filed last January to remove the waivers protecting the controversial Ohio PPAs from full FERC review,” it said. “This means if AEP and FE elect to proceed with the wholesale contracts, they will need to file the PPAs … and show among other things that the deals they negotiated with themselves satisfy FERC’s rules designed to protect against such affiliate abuse.”

‘Effectively Captive’

FERC said its “fundamental goal in categorizing certain customers as ‘captive’ is to protect customers served by franchised public utilities from inappropriately subsidizing the market-regulated or non-utility affiliates of the franchised public utility or otherwise being financially harmed as a result of affiliate transactions and activities. … Where, as here, circumstances demonstrate that a retail customer has no choice but to pay the costs of an affiliate transaction, they effectively are captive with respect to the transaction.”

FERC did agree with AEP and FirstEnergy on one point, rejecting the complainants’ claim that the PPAs would distort prices in PJM by subsidizing the continued operation of generation that would otherwise retire.

The commission said that PJM bidding behavior was not relevant to the affiliate abuse complaint and thus outside the scope of the cases. However, the commission noted that a third complaint filed by Calpine over the PPAs, in which PJM rules are central, remains pending (EL16-49). The complainants asked FERC to expand PJM’s minimum offer price rule to ensure the PPAs don’t distort May’s 2019/20 Base Residual Auction.

“By this order, we do not prejudge the outcome of that proceeding,” the commission said. (See Generators to FERC: Expand MOPR for Subsidized FE, AEP Plants.)

FERC took note of the jurisdictional implications of its ruling, insisting in the AEP order that its ruling “does not frustrate or usurp the Ohio commission’s role in protecting retail customers. Rather, this commission has an independent role to ensure that wholesale sales of electric energy and capacity are just and reasonable and to protect against affiliate abuse. The commission’s affiliate restrictions protect against captive customers of franchised public utilities cross-subsidizing market-regulated power sales affiliates. The affiliate PPA raises the potential for cross-subsidization from AEP Ohio’s retail customers – who are captive in the sense that they cannot avoid the non-bypassable charge – to AEP Ohio’s market-regulated power sales affiliate, AEP Generation.”

The commission used virtually identical language in its FirstEnergy order.

Reaction

Former Pennsylvania Public Utility Commissioner John Hanger said the rulings “are obviously going to throw a huge monkey wrench in the FirstEnergy and AEP plans.”

Hanger, now a private energy industry attorney, predicted the company’s PPAs “will have a short shelf life.” He applauded FERC’s moves.

FERC, he said, “is not being swept by the powerful forces in state capitals. Electric utilities are the 800-pound gorillas” in state politics, he said.

Former PUCO chairman Todd Snitchler, now with The Alliance for Energy Choice, said Wednesday night he was “obviously pleased” with the rulings after taking a cursory review but wanted more time before commenting further.

“Today, federal regulators stood up for customers and defended fair markets and competition, sending a clear signal to any utility trying to bail out their uneconomic power plants through political prowess,” the Environmental Defense Fund said. “FERC’s decision to block these bailouts will save Ohioans $6 billion while spurring energy innovation and reducing harmful pollution.”

Ohio Consumers’ Counsel Bruce Weston also celebrated the order. “In response to legal action by the Consumers’ Counsel and others, federal officials today provided Ohioans the benefits of competitive markets and lower rates that they did not receive in the state plans filed by FirstEnergy and AEP,” Weston said. “The federal ruling has the potential to save each of several million Ohio electric consumers hundreds of dollars over the next eight years, while protecting the competitive market envisioned by the Ohio legislature in 1999.”

SPP Awards First Order 1000 Project — But it May Not be Needed

By Tom Kleckner

SANTA FE, N.M. — SPP awarded its first competitively bid transmission project under FERC Order 1000 on Tuesday, but it may not be built because of declining load forecasts.

The RTO’s Board of Directors and Members Committee both voted to accept an industry expert panel’s (IEP) recommendation to award the 22.6-mile, 115-kV line from Walkemeyer to North Liberal in southwest Kansas to Mid-Kansas Electric.

spp, order 1000
The proposed Walkemeyer-North Liberal 115-kV line is in Seward County, in the southwest corner of Mid-Kansas Electric’s service territory.

Oklahoma Gas & Electric was selected as the alternative “designated transmission owner” should Mid-Kansas be unable to construct the project. Mid-Kansas and OG&E received the panel’s two highest scores among the 11 competitive proposals submitted to SPP.

Mid-Kansas CEO Stuart Lowry accepted congratulations from fellow members and gathered his employees in a group hug after the vote, before telling RTO Insider the company had proposed the project be re-evaluated. He later told members the Mid-Kansas and Sunflower Electric Power system has seen a 27% reduction in load forecasts within the project’s region.

Mid-Kansas is owned by five electric cooperatives members and a not-for-profit company, and managed and operated by Sunflower, a wholesale generation and transmission provider.

Mid-Kansas said the area has seen a drop in forecasted loads from oil and gas exploration. It also loses the auxiliary load of a nearby gas-powered generating plant when SPP doesn’t dispatch the plant. The load forecast that drove the need for the Walkemeyer project was conducted almost three years ago as part of SPP’s Integrated Transmission Planning 10-year assessment.

“I try to put myself in [the stakeholders’] shoes,” Lowry said. “This project is a reliability project, so it’s totally driven by load forecasts. We’re seeing a reduction in the region, so we made a decision we need to report on this. If the information is correct, we want to do what is best.”

Lowry said Mid-Kansas has contracted with Burns & McDonnell to provide an “independent set of eyes” on the need for the new line.

Mid-Kansas asked SPP last month to re-evaluate notices-to-construct it has already received for the two noncompetitive portions of the project, which include terminal upgrades at the existing North Liberal and Walkemeyer substations. The board granted staff’s request for an expedited review of the need for both NTCs, which were awarded last summer.

SPP CEO Nick Brown also mentioned the load-forecast changes at a Gulf Coast Power Association conference two weeks ago. (See Grid Execs Talk Cybersecurity, Renewables, Order 1000.)

Paul Suskie, SPP’s executive vice president of regulatory policy and general counsel, said SPP members are free under the Tariff to request project re-evaluations at any time.

“The request to restudy this line is a part of our stakeholder process that occurs every year,” he said. “SPP will re-evaluate this line as we have others in the past.”

Mid-Kansas’ winning bid received an 892.85 score on a 1,000-point scale from the IEP, 13% higher than OG&E’s proposal, which scored a 785.67. The other nine bidders were not identified.

Mid-Kansas was one of only two bidders to win 100 incentive points for providing a “detailed project proposal,” but it would have won even without it, the IEP said.

The IEP’s scoring methodology graded each respondent on engineering design, experience in project management, construction and operations, a rate analysis (estimated total cost, including financing, FERC incentives and any cost certainty guarantees by the bidder) and finance (including financial viability and creditworthiness).

The panel said the Mid-Kansas proposal met all of its evaluation criteria, receiving 90% of the possible finance points and contained the second-lowest 40-year net present value.

SPP Board of Directors Meeting, Order 1000
Steve Strickland, chairman of SPP’s industry expert panel, makes a point during Tuesday’s board meeting as FERC Chairman Norman Bay, center, and others listen. © RTO Insider

“Our recommendation was built around what the entire panel felt would a successful project,” said the panel’s chair, Steve Strickland, who spent 35 years with Entergy Arkansas. “We defined that as a project that operated as intended, was on schedule and under budget.”

The Mid-Kansas and OG&E proposals were very close with their engineering and construction cost estimates ($8.33 million versus $8.44 million, respectively) and NPV estimates ($10.57 million versus $10.15 million).

“This represents a lot of hard work by our staff. A lot of the credit goes to them,” said Lowry, naming Mid-Kansas COO Kyle Nelson, CFO Davis Rooney and Al Tamimi, vice president of transmission planning and policy at Sunflower. “There was a lot of uncertainty over the process, how the proposals would be evaluated … everyone learned a great deal.”

Formed in 2005, Mid-Kansas serves a combined 200,000 members in western and central Kansas. Its assets include 843 MW of natural gas, coal and wind generation and about 1,140 miles of transmission. Sunflower adds another 655 MW of generation and 1,205 miles of transmission.

SPP stakeholders developed and FERC approved a transmission owner selection process to comply with Order 1000, which required the removal of federal rights of first refusal for certain transmission projects.

The process began in June 2014, when interested parties had 180 days to respond to the Walkemeyer project’s request for proposals. The IEP was established in November, and shortly thereafter it began its review and evaluation of the 11 responses.

[Editor’s Note: An earlier version of this article incorrectly stated the net present value of the Mid-Kansas and OGE proposals in billions rather than millions. It also incorrectly stated that the noncompetitive portion of the project included a switching station.]

 

MISO Planning Advisory Committees Briefs

MISO is recommending that Michigan Electric Transmission Co. (METC) construct a portion of a proposed transmission line intended to upgrade supply for Coldwater, Mich., while rejecting expedited review for a broader proposal.

Coldwater project map (MISO) planning advisory committee briefsThe RTO is backing a portion of the proposed $65 million Coldwater load interconnection project that would provide the city an additional 18 MW of supply capability by 2017 via a 138-kV tap from an existing METC line. Parent company ITC Holdings sought expedited review of a larger project that would have included an additional 18 MW of capacity by 2021. (See “MISO Receives 1st Expedited Review Request,” MISO Planning Advisory Committee Briefs.)

MISO said it agreed with stakeholders at the Technical Study Task Force, which reviewed the project in March, that only the improvements necessary to manage Coldwater’s 2017 incremental load required expedited treatment. Less pressing work to meet the 2021 goal would be relegated to the MISO 2016 Transmission Expansion Plan.

Of Coldwater’s total load of 88 MW, 65 MW is currently supplied through a single 4.5-mile 138-kV transmission circuit, Thompson Adu, MISO senior manager of transmission expansion planning, told the Planning Advisory Committee last week. New industrial load is expected to push that total to more than 120 MW by 2026.

METC’s proposed radial supply line would carry 83 MW when completed, Adu said.

MISO Adds Tariff Provisions for Identical Market Participant-Funded Projects

MISO has revised its Tariff to comply with a December FERC order requiring a first-come, first-served selection procedure when more than one market participant proposes to fund the same transmission projects.

The process set out in the Tariff will mirror that already represented in a MISO business practices manual.

The issue was brought to light last year when Boston Energy Trading and Marketing and J. Aron & Co. both proposed to fund Ameren Illinois’ Effingham-Effingham NW 138-kV line in Illinois at an estimated cost of more than $1 million.

Boston Energy filed a complaint saying that MISO tried to force it to partner with J. Aron on the project based on language in a BPM but that it lacked Tariff authority to do so.

FERC sided with Boston Energy, saying MISO’s Tariff was unjust and unreasonable because it lacked provisions for processing market participant-funded transmission projects (EL15-89). The commission required new Tariff language that addresses how the RTO “will handle multiple, similar requests for market participant funding of a transmission upgrade.”

The Tariff revisions will mirror BPM language already vetted by the PAC. Adu said the new language will be filed with the commission by the June 20 compliance deadline.

MISO Order 1000 Compliance

MISO is nearing completion of its Order 1000 interregional compliance obligations, said Eric Thoms, the RTO’s manager of planning coordination and strategy.

FERC accepted MISO’s compliance filings with both SPP and Southeastern Regional Transmission Planning, while seeking clarification on cost allocation, interconnection projects and ownership rights in its joint filing with PJM (ER13-1944-001, et al.).

Meanwhile, MISO continues to pursue interregional efforts with its neighbors. At present, 14 projects near the MISO-SPP seam are being considered in MTEP16.

MISO and PJM have begun searching for “low-cost, quick-implementation upgrades” as part of their 2016 quick hits study process. Thoms said there was “value” in the quick hits studies, but the process needs to be formalized to reflect cost allocation.

“If we’re looking at low-hanging fruit … there’s no need for [multiple regional approval processes],” he said.

MISO and PJM have also completed two targeted studies from 2015 on the Michigan-Indiana and Quad Cities interfaces.

“We’ll continue to monitor this issue,” Thoms said.

— Amanda Durish Cook

FERC Rules on MISO Revenue Sufficiency Guarantee

By Amanda Durish Cook

FERC on Thursday cleared a backlog of disputes over MISO’s revenue sufficiency guarantee (RSG), issuing a quartet of orders in dockets dating back to 2009 concerning intermittent resources, headroom, cost allocation and resettlement procedures.

The commission:

  • Exempted intermittent resources from RSG charges when they respond to MISO curtailment orders (ER11-2275-003) but refused to rehear arguments that such resources should be exempt from RSG charges altogether (ER09-411- 005);
  • Upheld MISO’s continued use of a real-time headroom definition in its allocation of RSG charges (ER11-2275-002); and
  • Refused to rehear arguments about MISO’s RSG assessments on MISO customers making both virtual supply offers and electricity withdrawals (EL07-86-012, et al.).

Generation or demand response resources receive RSG payments if they are committed through the reliability assessment commitment (RAC) process after the close of the day-ahead markets and they receive insufficient real-time energy and operating reserve revenues to cover its production costs.

DA-and-RT-Revenue-Sufficiency-Guarantee-(RSG)-(MISO) FERC

Intermittent Resources

FERC’s order exempting curtailed intermittent resources from RSG charges was made effective July 2, 2011, rather than the May 2011 date sought by renewable generators. E.ON Climate and Renewables North America and NextEra Energy Power Marketing protested the later date, saying it subjected them to extra months of revenue sufficiency guarantee charges for “no just reason.”

FERC ruled the extra 60 days were reasonable because MISO needed extra time to adjust its systems and procedures to incorporate the exemption.

In the second case, the commission reiterated a compliance order rejecting a request to exempt intermittent resources from all RSG charges.

The commission cited an “extensive record” documenting that “increases and decreases in the real-time output of intermittent resources, as well as the reduced forecasts or unavailability of such resources, may cause real-time revenue sufficiency guarantee costs.”

FERC said the rehearing requests from more than 15 companies only repeated arguments it previously rejected and that exempting intermittent resources from RSG charges “would unfairly shift costs to other market participants.”

The companies had claimed MISO’s Independent Market Monitor overstated intermittent resources’ contributions to the make-whole costs and a MISO analysis didn’t take into account several intermittent characteristics, including transmission de-rates, grandfathered transmission agreements, system topology and changes in loop flows.

FERC said that while it recognized changes between thermal and intermittent resources, the differences didn’t warrant an exemption.

Headroom Definition

In a third ruling, FERC upheld MISO’s definition of real-time headroom — the difference between the real-time economic maximum dispatch and real-time dispatch targets for resources — in its allocation of RSG charges.

Under methodology proposed by MISO and accepted by FERC in 2011, the headroom charge was calculated based on the lesser of headroom or the aggregate of the hourly economic maximum dispatch amounts of all resources committed in any RAC process. In the Thursday order, FERC clarified that the headroom definition isn’t limited to intra-day RAC commitments and includes commitments made in MISO’s forward RAC process.

MISO’s Transmission-Dependent Utilities sector had said MISO’s headroom cap should be eliminated or limited to include only headroom contributed by resources committed in the intra-day RAC. The commission said the forward reliability assessment commitment process is part of the real-time commitment process, and therefore should be included.

A group of six financial marketers said FERC headroom costs should be allocated to all market participants based on market load ratio, rather than assessed on virtual offers and deviations. FERC responded that headroom allocations are already based on market load share.

The order also upheld MISO’s allocation of exempted deviations, which were challenged by Westar Energy on the basis that too many costs are allocated to deviations than to load. FERC brushed the complaint aside. “As the commission has stated in previous revenue sufficiency guarantee charge proceedings, there is no such thing as an ideal and static proportion of costs that should be allocated to any activity. Rather, a reasonable allocation is one that reflects cost causation principles,” FERC said.

Virtual Offers

In the final order, FERC refused to rehear arguments about flaws in RSG proceedings first brought up nine years ago. In 2007, Ameren, Northern Indiana Public Service Co. and eight other utilities alleged discrimination in MISO’s RSG rate because it was assessed on only a subgroup of MISO customers making both virtual supply offers and electricity withdrawals. MISO was directed to modify its Tariff so the RSG applied to all cleared virtual supply offers. The RTO then began stakeholder discussions on refunds and resettlement for the period of Nov. 5, 2007, to Nov. 9, 2008.

Several companies requested rehearing on the matter. Tenaska Power Services wanted FERC to order MISO to issue refunds with interest. Seven financial marketers asked for MISO’s RSG to be recalculated by adding exempted deviations back into the formula. The bulk of the requests claimed that MISO didn’t hold any stakeholder meetings on the resettlement.

FERC refused all rehearing requests, saying the issues in the case were “strictly limited to the compliance requirements” and the companies’ requests were beyond the scope of the order. “The resettlement process undertaken by MISO, reflecting its interpretation of the MISO tariff with respect to exempted deviations, has been the subject of proceedings in docket no. ER04-691,” FERC noted.

FERC Upholds PJM’s Treatment of Demand Response

By Suzanne Herel

FERC last week denied five requests for changes in PJM’s treatment of demand response, rebuffing filings by the Independent Market Monitor, DR providers, industrial customers and Public Service Enterprise Group.

The commission rejected an allegation by the Monitor that PJM doesn’t treat DR in a way comparable with generation capacity resources. The Monitor said it should be subject to a must-offer requirement in the day-ahead energy market as well as the energy offer cap (EL14-20). (See Monitor Asks FERC for Must-Offer on Demand Response.)

“The commission has … explained that comparability does not require that generation resources and demand response resources be subject to the same operational parameters in every circumstance,” FERC said.

Viridity Energy had filed a complaint that PJM’s compensation provisions are discriminatory to capacity-only resources because an end-use customer that registers with one curtailment service provider (CSP) for capacity and a second CSP for energy does not receive a guaranteed energy payment when called to reduce load in response to an emergency.

FERC cited reliability issues and the avoidance of double payments in denying the complaint (EL12-54).

The commission said the differences in compensation were justified by the need to avoid errors in measurement and verification by customers represented by two different CSPs from inadvertently or intentionally submitting duplicate offers for the same megawatts covering the same time period. “Duplicate offers, as PJM notes, could create reliability problems by erroneously indicating to PJM’s operators that they will be getting twice the demand reduction that is actually available during an emergency condition. As PJM further notes, market participants, in this circumstance, could be required to pay twice for the same reduction.”

EnergyConnect and Comverge were denied rehearing of a May 2014 order accepting rules increasing the operational flexibility of DR. FERC also found that PJM’s compliance filing satisfied the requirements of the May order (ER14-822).

The commission also denied a rehearing request from the PJM Industrial Customer Coalition regarding a January 2014 order that capped PJM’s procurement of certain limited-availability DR products. The order noted that PJM’s limited and extended summer DR products will be eliminated as a result of the new Capacity Performance rules (ER14-504).

Finally, FERC denied a rehearing request from PSEG that challenged a requirement that DR providers submit certain information before the Base Residual Auction proving their ability to perform when needed (ER13-2108). In part, the commission found that the general statement of obligation applies to all capacity resources and is not specific to DR.

Chairman Norman Bay said that the Supreme Court upholding FERC’s jurisdiction over DR has allowed the commission to begin clearing a backlog of DR cases. “There were a number of DR matters that could not be resolved until the Supreme Court issued its decision,” he said.

Company Briefs

Consumers Energy decommissioned the last of its Michigan “Classic Seven” coal-fired turbines in response to tighter EPA emissions restrictions. The B.C. Cobb Generating Facility on Muskegon Lake ended its 67-year run in mid-April.

ConsumersSourceConsumersThe turbines were retired in staggered order in consultation with MISO. The turbines included two at B.C. Cobb, two at the D.E. Karn/J.C. Weadock Generating Complex in Essexville and three at the J.R. Whiting Generating Complex in Luna Pier.

Consumers is currently outfitting five of its operational coal-fired plants with scrubber systems to meet emissions standards.

More: MLive

LG&E/KU Unveil Kentucky’s Largest Solar Array

LGESourceLGEKentucky’s largest solar facility was inaugurated last week by Louisville Gas & Electric and Kentucky Utilities. The E.W. Brown Generation Station in central Kentucky contains about 44,600 solar panels, capable of producing 19,000 MWh of electricity annually.

“We’re embarking on a new era and introducing a new source of energy to our generation portfolio that will work in concert with our coal, natural gas and hydroelectric fleet,” Paul Thompson, chief operating officer for the PPL-owned utilities, said at an unveiling ceremony.

Thompson said the new facility will allow LG&E and KU to study how commercial-scale solar energy is impacted by factors such as cloud cover and “how it integrates with the existing generating units.”

More: The Advocate-Messenger

Exelon, RES Join to Build 10-MW Energy Storage Unit

exelongenerationsourceexelonExelon Generation and Renewable Energy Systems are joining to build a 10-MW energy storage facility in Clinton County, Ohio, that is expected to be operational by the end of the year.

RES, which operates 48 MW of storage facilities, will oversee construction of the project, which Exelon Generation will operate. The unit will comprise three tractor-trailer-sized modular units near a substation for easy interconnection with PJM.

The facility will provide frequency regulation for the RTO. “Exelon’s deployment of battery storage technology provides customers and grid operators with innovative solutions to meet their technical requirements and enhance system reliability,” said Corey Hessen, vice president of Exelon Generation Development.

More: Exelon Generation

Con Ed Investing in More Natural Gas Pipelines

conedsourceconedConsolidated Edison is investing about $975 million in a joint venture to own natural gas pipelines and storage serving the northeast markets.

Stagecoach Gas Services will be managed by Crestwood Equity Partners and own assets in Pennsylvania and New York.

Con Ed announced the creation of Con Edison Transmission, a unit to invest in pipeline and transmission line projects, in January. Like other utilities, Con Ed is investing more in pipelines as electricity demand slows.

More: Bloomberg

Exelon Warns of Possible Clinton Nuke Closure

clintonsourcewikiAlthough it cleared the 2016/17 MISO capacity auction, the Clinton nuclear station may not stay open after May 31, 2017, without some sort of subsidies, warned Exelon CEO Chris Crane.

“Without urgent action on the policy front, we will have no choice but to prepare for a potential early retirement in the face of continued financial losses at our Clinton nuclear plant,” he said. “The loss of this plant would have significant economic impacts on southern Illinois and erase the environmental benefits equal to 80% of the wind installed in Illinois, making it significantly harder and more expensive for the state to meet its carbon reduction goals.”

Exelon is in the middle of a hard lobbying campaign in Illinois, seeking policy changes that would reward Clinton, and its five other nuclear stations in Illinois, for being carbon-free.

More: Exelon

SunEdison’s Rise in Solar Industry Ends in Bankruptcy

sunedisonsourcesunedisonSunEdison, the St. Louis-based company that shot to the top of American solar energy companies, filed for bankruptcy protection last week after multiple acquisitions left the company strapped for cash.

Analysts say the cause of the company’s demise stems from unwise investments, not an inherent problem with the solar industry. Much of the company’s growth occurred through a rapid series of large acquisitions, encumbering itself with substantial debt.

“Our decision to initiate a court-supervised restructuring was a difficult but important step to address our immediate liquidity issues,” CEO Ahmad Chatila said.

More: The Associated Press

GridLiance Adds Seattle CFO To its Leadership Team

bishopgridliancesourcegridliance
Bishop

GridLiance last week announced it had hired Seattle City Light CFO Jeff Bishop as its senior vice president, CFO and treasurer.

Bishop has spent 15 years in the industry, including financial leadership roles at PacifiCorp. He holds two bachelor’s degrees: one in accounting from Washington State University and another in zoology from the University of Washington.

“Municipal and consumer-owned power agencies, which have historically been unable to invest in large-scale, regional transmission projects, will benefit from GridLiance’s forward-thinking approach,” Bishop said.

More: GridLiance

Wind Farm Being Developed Near Colstrip Plant

Clearwater Energy is laying the groundwork for a 300-MW wind farm in eastern Montana, near transmission infrastructure that now serves the coal-fired Colstrip Power Plant near Billings.

The 500-kV power lines and a substation are big enough to accommodate Colstrip and the 300-MW Clearwater project. The Bonneville Power Administration, NorthWestern Energy and other stakeholders in the transmission lines serving Colstrip have discussed upgrading the transmission system to 700 MW. The Clearwater project is being planned to fill that extra capacity if it materializes.

More: Missoulian

Northern Pass Tx Line Contractors Named

Eversource Energy has named the contractors and material suppliers for the $1.6 billion Northern Pass transmission line, which is awaiting final state and federal permits.

Eversource named Quanta Service subsidiary PAR Electrical Contractors as general contractor. Burns and McDonnell Engineering will continue as part of the project team. The ABB Group will design and build the line’s underground section and a converter station in Franklin, N.H.

More: New Hampshire Union Leader

PPL Completes Northeast-Pocono Reliability Project

PPL Electric Utilities last week completed its $350 million Northeast-Pocono Reliability Project — more than a year before its original target date.

The 60-mile 230-kV line, which includes three new substations, should mean fewer and shorter outages for customers in Pennsylvania’s Lackawanna, Monroe, Wayne, Pike
and Luzerne counties, the company said. It’s the second major transmission project completed by PPL in the past year, following the $648 million Susquehanna-Roseland line, which was completed in May 2015.

While construction on Northeast-Pocono is complete, the company said land restoration will continue through the end of the year.

More: PPL

FERC Orders Further Changes to NYISO RMR Rules

By William Opalka

FERC told NYISO last week that proposed changes to its rules for reliability-must-run generators are insufficient, ordering another compliance filing in 60 days.

FERC, NYISO, reliability-must-run agreements
Cayuga Plant Source: Wikipedia

In February 2015, the commission found NYISO’s Tariff unjust and unreasonable because it lacked rules governing the retention and compensation of generating units needed for reliability. FERC took action after several coal-fired and nuclear generators in western New York announced their closures and the ISO was unable over nearly four years to win stakeholder consensus regarding uniform compensation rules for RMR units. (See FERC Orders NYISO to Standardize RMR Terms in Tariff.)

On Thursday, the commission said the ISO’s revised rules complied only in part with its directive (ER16-120, EL 15-37).

The commission approved the ISO’s use of going-forward costs as a compensation mechanism for generators and its use of net present value to compare solutions to reliability concerns. But it rejected the ISO’s proposed role for the New York Public Service Commission, its cost allocation proposal and its plan for bidding RMR generators into capacity auctions.

‘Gap Solution’

NYISO proposed adding its RMR rules to its existing “gap solution” process. The gap solution is currently triggered when the ISO’s biennial reliability planning process determines that neither market-based nor regulated proposals will address a reliability need quickly enough, or if its Board of Directors — after consulting with state regulators — determines there is an imminent reliability threat.

Under the ISO’s proposal, it would solicit gap solution — generation, transmission or demand response — and market-based solution proposals when it identifies a reliability need that would result from a generator deactivation.

If there are no viable market-based solutions, the ISO would provide the PSC with a list of transmission and DR gap proposals. The ISO would enter into an RMR agreement only if there are no viable non-generation solutions or if the PSC does not select such a solution from the list provided by the ISO.

FERC said the ISO’s plan was inconsistent with Order 1000, improperly delegated authority to the PSC and could lead to inefficient transmission development.

The commission also rejected a proposal that generators provide 365 days’ notice before deactivation, more than doubling the 180 days required by the PSC. Generators had protested that the proposed notice period was “unreasonably long.”

FERC did not rule on the merits of the extended time frame but said it would address the timing issue after NYISO proposes Tariff amendments outside of the gap solution process. The commission further said it could not determine whether a generator should be compensated during the notice period and at what level.

Capacity Pricing

FERC also rejected the ISO’s proposed cost allocation for RMR generators and transmission gap solutions as inconsistent with Order 1000 and its plan to bid RMR generators into its capacity auction at prices above $0/kW-month. “It is more efficient for RMR generators to offer their [unforced capacity] at $0.00/kW-month as ‘price-takers,’” FERC said.

It accepted in part the ISO’s provisions to prevent generators from “toggling” between RMR compensation and market-based rates, requiring additional protections.

FERC also denied rehearing of a PSC complaint that FERC’s February 2015 order encroached on its jurisdiction. (See FERC Interfering with Reliability Order, NYPSC Says.)

FERC Open Meeting Briefs

WASHINGTON — A May 13 FERC technical conference reviewing generator interconnection procedures will include a discussion on the interconnection of energy storage resources (RM16-12, RM15-12).

FERC-commissioners-listen-to-National-Labs-presentations-content-web
FERC commissioners listen as representatives from the Energy Department’s National Laboratories give a presentation on grid modernization. © RTO Insider.

The tech conference was scheduled in response to a 2015 petition by the American Wind Energy Association to revise the commission’s pro forma large generator interconnection agreement. Other topics to be discussed include the current status of interconnection queues and transparency in the interconnection study process.

The conference was brought up by FERC Chairman Norman Bay during a presentation staff gave the commission at its open meeting last week on the data requests it sent six grid operators regarding their rules for energy storage participation in the wholesale markets. The storage issues slated for discussion at the conference are largely the same as those the RTOs will address in their responses to the data requests, which are due May 2. (See FERC to Examine RTO Roles for Energy Storage.)

“Energy storage is one of the big potential game changers in the energy industry,” Commissioner Tony Clark said. “This line of inquiry that we’re opening and the responses we’re going to get back I think are going to be tremendously important.”

National Labs Brief FERC on Grid Modernization

Representatives from the Department of Energy and its national laboratories said that increased communication and cooperation with FERC will be needed in order to help them in their efforts to modernize the grid.

These efforts — including integrating renewable energy resources and energy storage, and increasing protection against cyber threats — were detailed in a series of presentations at the commission’s open meeting last week. The integration of new technologies will result in a paradigm shift in how energy is generated and used, they said.

One of “the key trends and themes that we’re reinforcing is the evolution towards more distributed control,” said Jeff Dagle, chief electrical engineer at Pacific Northwest National Laboratory. “Historically, we’ve forecasted demand and dispatched supply. I think increasingly in the future, we’ll be forecasting supply and dispatching demand.”

Chuck Goldman, of the Lawrence Berkley National Laboratory, urged FERC to consider having its senior staff participate in the advisory committees on some of the labs’ projects. He also said the commission should “think about the kinds of [research and development] that might be appropriate for ISOs that’s in the public interest [and] that can deal with grid modernization issues.”

– Michael Brooks

FERC Rejects Rehearing on SPP-WAPA JOA

By Tom Kleckner

FERC last week accepted revisions to SPP’s joint operating agreement with Western Area Power Administration-Upper Great Plains Region (WAPA-UGP), denying rehearing and clarification requests by MISO and 23 of its transmission owners (EL12-60, ER12-1586).

SPP Plus Integrated System Map - FERC SPP-WAPA Joint Operating Agreement (JOA)The commission’s April 21 order granted SPP and the Integrated System’s request for clarification that the term “energy exchange” reflects their intent that the JOA does not affect the transmission rights or service of third parties.

MISO and its TOs had protested FERC’s September 2012 order accepting the JOA, which was filed in April 2012 as a precursor to the IS’ membership in SPP. They said part of the JOA would be “incompatible” with market-to-market coordination between MISO and SPP when the latter’s Integrated Marketplace began operating, and that the agreement equated to “assessing compensation for loop flow.”

FERC rejected both arguments. The IS, comprising WAPA-UGP, Basin Electric Power Cooperative and Heartland Consumers Power District, became full transmission-owning members of SPP in October.

The commission clarified that that sections 5.4-5.6 of the JOA are the parties’ method for addressing contract path capacity determinations. The commission affirmed its prior determination that the language does not violate market-to-market principles or constitute unauthorized loop flow compensation.

“As the commission stated elsewhere in the Sept. 18 order, sections 5.4-5.6 of the [WAPA-SPP] JOA do not govern loop flow; rather, loop flow is governed by the congestion management process.”